QleanAir S 30 Safety

Designed for harsh
environments with high
demands on safety

All of our S-line Safety smoking cabins are designed to meet the strictest fire and safety regulations. In addition to being completely non-flammable, they have several added safety features, such as laminated safety glass and a safety net in the roof panel. S 30 Safety is the smallest of the S-line Safety units, with room for two smokers at a time. The smoking cabin captures the smoke before it is able to spread, protecting non-smokers without inconveniencing smokers. For workplaces, this means an improved social environment and increased productivity, and in other environments, it contributes to a healthier, safer, and more pleasant environment to stay in.

Loading...

Key components of the S 30 Safety smoking solution

  • Multi-stage filtration and preventive service ensure function and efficient air cleaning over time
  • HEPA 14 filter, classified by EN 1822 standard, ePM10 75% (M6) filter, and multiple layers of activated carbon
  • Capacity of up to two simultaneous smokers, 4500 cigarettes/service and airflow up to 700 m³/h
  • Quiet operation, <30-44 dB(A)
  • Robust laminated security glass and A2 classified fireproof materials
  • Clean, odorless, and fireproof with our patented ash handling system (AHS)
  • Operates independently of ventilation, using regular power socket
  • Delivered as a service, hassle-free installation, service and Lifetime Performance Guarantee included
Loading...
Loading...

Recommended areas
of application

Our S-line Safety units have been developed in partnership with some of our high-demand clients to meet their strict fire and safety regulations. S 30 Safety is a great solution for spaces such as healthcare and other care facilities, high-security facilities, institutions, production facilities, logistics centers, warehouses, and different types of offshore facilities. The main use of our smoking cabins is to protect non-smokers from secondhand smoke and to create a pleasant indoor environment free from odors. Without convenient smoking solutions, smokers tend to go for unsafe indoor smoking or smoking outside of the facility’s entrance, which causes the smoke to spread into the facility. In workplaces, inconveniently placed smoking areas often lead to unnecessarily long smoke breaks. Thankfully, all of these challenges can be solved with the right smoking cabin solution for your facility.

Benefits

The S 30 Safety smoking cabin protects non-smokers from second- and third-hand smoke while eliminating odors caused by the smoke, making the facility’s environment more pleasant to reside in. S 30 Safety captures the tobacco smoke before it is able to spread and removes its odors, harmful gases and particles through a multi-stage filtration system before releasing the cleaned air back into the room. By doing so, the smoking cabin protects non-smokers from harmful particles and unpleasant odors, while allowing smokers and non-smokers to stay in the same space, creating a better social environment. The smoking cabin also eliminates the issue of having to walk far distances to get to designated smoking areas, making smoke breaks shorter and safer, and, in turn, increasing productivity. S 30 Safety is equipped with several safety features, such as our patented fireproof ash handling system, a security net in the roof panel, a net covering the air outlets, and a secure holder for lighters. It’s the perfect solution for any facility that struggles with smoking-related challenges and needs a space-efficient solution that meets strict fire and safety regulations.

Safe and healthy
indoor air

fireproof

A2 classified
-fireproof materials

Robust laminated
security glass

Hassle-free installation and use

Hassle-free installation
and use

Odorless ash
handling system

Lifetime Performance
Guarantee

How it works S 30

The technology behind the solution

1. Capturing the smoke

A smoke free environment can on only be created if the polluted air is captured before it spreads. The S 30 Safety unit makes this possible. The air inlets are strategically placed above the table and send the polluted air into our powerful, multi-stage air filtration system.

2. Filtration of odors, gases and particles

Through multiple highly efficient HEPA 14, ePM1 75% (M6), and activated carbon filters, tobacco-specific gases, particles, and odors are captured and removed from the air.

3. Cleaned air is returned to the environment

After the air has been cleaned of odors, gases, and particles, it is returned into the room, without any detectable traces of cigarette smoke.

4. Fireproof ash handling system

Our unique, fireproof ash handling system (AHS) handles the disposal of ashes and cigarette ends. A patented valve solution keeps it airtight to avoid smoke residue commonly found in traditional ashtrays.

Model QleanAir S 30 Safety
 
Dimensions (w x h x d) 1477 × 2051 × 785 mm
Assembly height 2150 mm
Material Aluminum/glass/steel
Weight 290 kg
Capacity 4500 cigarettes/service
Smokers Up to 2

Airflow Up to 700 m3/h
Particle filters ePM10 75% (M6) + HEPA 14
Gas filters Multiple layers of activated carbon filters

Sound level <30-44 dB(A)
Power supply 100/220-240V, ~50-60 Hz
Energy consumption 60-230W
Control IR sensor

Certifications and compliance   
 
Model: QleanAir S 30 Safety
Dimensions (w x h x d)
1477 × 2051 × 785 mm
Assembly height
2150 mm
Material
Aluminum/glass/steel
Weight
290 kg
Capacity
4500 cigarettes/service
Smokers
Up to 2

Airflow
Up to 700 m3/h
Particle filters
ePM10 75% (M6) + HEPA 14
Gas filters
Multiple layers of activated carbon filters

Sound level
<30-44 dB(A)
Power supply
100/220-240V, ~50-60 Hz
Energy consumption
60-230W
Control
IR sensor

Certifications and compliance
  

Related products

QleanAir S 30

Compact smoking cabin for 1-2 persons.

QleanAir S 40 Safety

A smoking cabin specially designed for harsh environments with high demands on safety. Suitable for up to four persons.

QleanAir FS 10 Carbon

Ceiling-mounted and efficient against smoke, odors, and gases.