QleanAir S 40

Medium sized
smoking cabin for
up to four persons

Our S-line smoking cabins meet the highest demands regarding fire safety, and are all A2 classified by the German MFPA test institute. The S 40 can fit up to four smokers at a time, making it a great solution for any facility struggling with the challenges that come with frequent smoking. S 40 smoking cabin captures the smoke before it can spread, protecting non-smokers without inconveniencing smokers. In other words, S 40 contributes to a healthier, safer, and more pleasant environment to stay in, as well as an improved social environment and increased productivity.

Loading...

Key components of the S 40 smoking cabin solution

  • Multi-stage filtration and preventive service ensure function and efficient air cleaning over time
  • HEPA 14 and ePM10 75% (M6) filters, classified according to EN 1822/ISO 1890 standards, and multiple layers of activated carbon
  • Capacity of up to four simultaneous smokers, 4500 cigarettes/service and airflow up to 700 m3/h
  • Quiet operation, <30-44 dB(A)
  • Clean, odorless, and fireproof with our patented ash handling system (AHS)
  • Operates independently of ventilation, using regular power socket
  • Delivered as a service, hassle-free installation, service and Lifetime Performance Guarantee included
Loading...
Loading...

Recommended areas
of application

S 40 has been specifically designed for spaces where frequent smoking occurs and that have strict fire protection requirements, such as offices, conference centers, hotels, casinos, healthcare and other care facilities, production facilities, logistics centers, and warehouses. All of our smoking cabins are designed with non-smokers in mind: their main main use is to protect non-smokers from secondhand smoke, as well as creating a pleasant indoor environment free from odors. Without convenient smoking solutions, smokers tend to go for unsafe indoor smoking or smoking outside of the facility’s entrance, which causes the smoke to spread into the facility. In workplaces, inconveniently placed smoking areas often lead to unnecessarily long smoke breaks. By using our smoking cabin, you can solve these challenges and increase productivity and create a pleasant, healthy, and safe environment for everyone.

Benefits

S 40 captures the smoke before it can spread and uses a multi-stage filtration system to remove harmful gases and particles from the air before the cleaned air is released back into the room. This way, the smoking cabin protects non-smokers, while allowing smokers and non-smokers to stay in the same space, creating a better social environment. The smoking cabin also eliminates the issue of having to walk far distances to get to designated smoking areas, making smoke breaks shorter and safer, and, in turn, increasing productivity. S 40 is certified by the world-leading test institute Leipzig Instituete for Materials Research and Testing, and is a great solution for any facility that struggles with the challenges of frequent smoking and needs a solution that meets the strict requirements for fire protection.

The smoking cabin is equipped with our patented fireproof ash handling system and comes in both an open and a closed version depending on your specific needs.

HEPA 14
filtration

fireproof

A2 classified
-fireproof materials

Increased
productivity

Hassle-free installation and use

Hassle-free installation
and use

Safe and odorless
ash handling system

Lifetime Performance
Guarantee

The technology behind the solution

1. Capturing the smoke

A smoke-free environment can on only be created if the polluted air is captured before it spreads. The S 40 unit makes this possible and the strategically placed air inlets, above the table, send the polluted air into our powerful, multi-stage air filtration system.

2. Filtration of odors, gases, and particles

Through multiple highly efficient HEPA 14, ePM10 75% (M6), and activated carbon filters, tobacco-specific odors, gases, and particles are captured and removed from the air.

3. Cleaned air is returned to the environment

After the air has been cleaned of gases, particles, and odors, it is returned into the room, without any detectable traces of cigarette smoke.

3. Fireproof ash handling system

Our unique, fireproof ash handling system (AHS) handles the disposal of ashes and cigarette ends. A patented valve solution keeps it airtight to avoid smoke residue commonly found in traditional ashtrays.

Model QleanAir S 40
  Open Closed
 
Dimensions (w x h x d) 1941 × 2051 × 785 mm 1945 × 2051 × 840 mm
Assembly height 2150 mm 2150 mm
Material Aluminum/glass/steel Aluminum/glass/steel
Weight 247 kg 260 kg
Capacity 4500 cigarettes/service 4500 cigarettes/service
Smokers Up to 4 Up to 4

Airflow Up to 700 m3/h
Particle filters ePM10 75% (M6) + HEPA 14
Gas filters Multiple layers of activated carbon

Sound level <30-44 dB(A)
Power supply 100/220-240V, ~50-60 Hz
Energy consumption 60-230W
Control IR sensor

Certifications and compliance   
 
Model: QleanAir S 40
Open
Dimensions (w x h x d)
1941 × 2051 × 785 mm
Assembly height
2150 mm
Material
Aluminum/glass/steel
Weight
247 kg
Capacity
4500 cigarettes/service
Smokers
Up to 4
Closed
Dimensions (w x h x d)
1945 × 2051 × 840 mm
Assembly height
2150 mm
Material
Aluminum/glass/steel
Weight
260 kg
Capacity
4500 cigarettes/service
Smokers
Up to 4

Airflow
Up to 700 m3/h
Particle filters
ePM10 75% (M6) + HEPA 14
Gas filters
Multiple layers of activated carbon

Sound level
<30-44 dB(A)
Power supply
100/220-240V, ~50-60 Hz
Energy consumption
60-230W
Control
IR sensor

Certifications and compliance
  

Related products

QleanAir S 60

A large sized smoking solution for your employees in for example production facilities, logistics centers and warehouses.

QleanAir S 40 Safety

A compact smoking cabin specially designed for harsh environments with high demands on safety. Suitable for up to four persons.

QleanAir SF 4000 X